5223 Double-Link Beam Load Cell
Revere
Model 5223 is a hermetically-sealed, end loaded, center-supported double-ended shear beam.
Capacities: 50k to 100k lbs
Nickel-plated element
Certified to OIML R60 3000d and NTEP class IIIL 10000 divisions
Teknik dosyalar
| SKU | Capacity | Cable Length | Mounting Thread Type | Output | Approval / Safety Code |
|---|---|---|---|---|---|
| 05223-050E-B1-03F | Capacity : 50 klb | Cable Length : 40 ft | Mounting Thread Type : NT | Output : Standard Product | Approval / Safety Code : FM |
| 05223-065E-B1-01F | Capacity : 65 klb | Cable Length : 40 ft | Mounting Thread Type : NT | Output : Standard Product | Approval / Safety Code : FM |
| 05223-065E-B1-07F | Capacity : 65 klb | Cable Length : 40 ft | Mounting Thread Type : NT | Output : Same as Standard Except check L&H on 100K Dead Weight | Approval / Safety Code : FM |
| 05223-100E-B1-05F | Capacity : 100 klb | Cable Length : 40 ft | Mounting Thread Type : No Thread | Output : Standard Product | Approval / Safety Code : FM |
| 05223-050E-B1-01F | Capacity : 50 klb to 60 klb | Cable Length : 40 ft | Mounting Thread Type : NT | Output : 3.0 mV/V | Approval / Safety Code : FM |
| 05223-065E-B1-00N | Capacity : 65 klb | Cable Length : 60 ft | Mounting Thread Type : NT | Output : 3.0 mV/V | Approval / Safety Code : Cannot be Converted to ATEX/FM |
| 05223-065E-B1-03F | Capacity : 65 klb | Cable Length : 40 ft | Mounting Thread Type : NT | Output : 3.0 mV/V | Approval / Safety Code : FM |
Description
Model 5223 is a hermetically-sealed, end loaded, center-supported double-ended shear beam.
This product is suitable for a wide range of truck and rail scales. It is designed to use parallel link
loading, considered by many weighing experts to be advantageous when compared to other loading techniques.
Fully-welded stainless-steel seals ensure high environmental integrity, and provided that additional cable sealing is used, occasional submersion can occur without damage.
These products meet the stringent Weights and Measures requirements throughout Europe.
Features
- Capacities: 50k to 100k lbs
- Nickel-plated element
- Certified to OIML R60 3000d and NTEP class IIIL 10000 divisions
- Sealing: IP67 (DIN 40.050)
- Low-profile, self-checking, and self-centering
- Optimized design specially for weighbridge use
Options
- Conduit adapter
- FM approved for use in potentially explosive atmospheres
Certifications
| Parameter | Value | Unit | ||
|---|---|---|---|---|
| Rated capacity (lbs) | 50k, 65k, 100k | lbs | ||
| NTEP/oiml accuracy class | NTEP IIIL | Non-Approved | C3 | |
| Max. no. of intervals (n) | 10000 | — | 3000 | |
| Rated output R.O | 3 | mV/V | ||
| Rated output tolerance | 0.003 | ±%mV/V | ||
| Zero balance | 1 | ±%FSO | ||
| Non-repeatability | 0.0100 | 0.0100 | 0.0100 | ±%FSO |
| Creep error | — | 0.0300 | 0.0245 | ±%FSO |
| Ultimate over load | 300 | % of R.C | ||
| Excitation voltage | 5 to 18 | VDC or VAC RMS | ||
| Max. excitation voltage | 20 | VDC or VAC RMS | ||
| Input resistance | 700±7 | Ω | ||
| Output resistance | 700±7 | Ω | ||
| Insulation resistance | ≥5000 | MΩ | ||
| Environmental protection | IP67 | |||
- FSO - Full Scale Output
- All specifications subjects to change whithout notice.
Applications
- Truck scales
- Railroad track scales
- “Legal-for-Trade” tank, bin and hopper weighing

Üreticinin özgün İngilizce teknik içerikleri korunmuştur. Teknik PDF belgeleri ürün sayfalarından indirilebilir.